CLEVER LOGGER NEWS

Tip of the Month – July 2024

Creating a temperature report for Council or Public Health accreditation takes just a few clicks.

Get a fridge report in just a few clicks

If you are storing temperature-sensitive items, such as medicine or food, there will almost certainly come a time when you need to produce a report for an inspector.

Clever Logger makes it a piece of cake.

Let’s run through the process for, as an example, a vaccine fridge after a power failure.

Here’s our graph…

We can see that the power was out from about 5pm until about 9am.

So let’s create a report from a couple of hours on either side of those times.

twice-daily-report

Click on Reports in the menu.

add report button

Click on the Add Report button in the top right corner of the screen.

1

run report screen

Click on the Create button in the Run Report Now panel

2

custom report

Click Create to select the Custom Report

3

Select All Readings as the report  type. This will give us the 5‑minute data for our selected time period.

4

report options

Select the logger.

5

report options

Select PDF as the Report Type. 

6

Give your report a name

report date picker

Select the start date and time and end date and time. In this case, I have chosen to get data from a couple of hours before and after the breach.

Follow the instructions to send the report to one of your users, and/or download the report. Click the button below to see what the report looks like in real life.

30-DAY FREE TRIAL

You're going to love Clever Logger

To prove it, we’ll send you a Starter Kit to try out for a whole month.

Set it up, have a play, explore the features – obligation free.

If you love it, just let us know.

If not, just send it back.

Clever Logger temperature logger with external probe

Logger with Dual Temperature Sensors

QUICK SPECS
Model CLD-01
Type Temperature only with Dual Sensors
Temperature Range Internal sensor: -23°C to +60°C
External sensor: -40°C to +80°C
Humidity Range N/A
Battery Type CR2450
Battery Life Replace every 12 months
Accuracy Internal Sensor:
±0.3℃ (0℃ to +60℃)
±0.3℃ to ±0.7℃ (other temperatures)
External Probe:
±0.5℃ (-20℃ to +40℃)
±1℃ (other temperatures)
Offline Memory approx 24 days logging at 5 minute intervals
Clever Logger temperature logger with external probe

Logger with External Probe

QUICK SPECS
Model CLX-01
Type Temperature only with Probe
Temperature Range -40°C to 60°C
Can operate up to 80°C for short periods
Humidity Range N/A
Battery Type CR2450
Battery Life Replace every 12 months
Accuracy ±0.5℃ (-20℃ to +40℃)
±1℃ (other temperatures)
Offline Memory approx 24 days logging at 5 minute intervals