How Clever Logger works

Is Clever Logger right for me

Clever Logger for vaccine fridges

Clever Logger for food safety

The optimum solution for vaccine fridges

Clever Logger Dual Sensor Temperature Logger (CLD-01)

This model has two temperature sensors – an internal sensor and external probe.

When placed in a vial of glycol (or a similar non-freezable liquid), the probe accurately mimics vaccine temperatures.

Requires Gateway to connect to the internet.
Remember, there are NO ongoing fees with Clever Logger.

Part No: CLD-01

No card? No problem!

Calls us on 1300 80 88 89 or send orders to [email protected]

IN STOCK AND READY FOR IMMEDIATE DISPATCH

Clever Logger logger and vial
BULK PRICING
QuantityLogger OnlyWith Vial
10 or more$171.60$195.80

No more manual downloading

Clever Logger to Gateway-to-Internet

Traditional loggers have to be manually downloaded to get their data.

Clever Logger changes that. The loggers broadcast their temperatures and the gateway picks them up and saves them to the internet every few minutes.

This gives you a “live” log of temperatures available on any internet device (computer, tablet, phone), anywhere in the world on the Clever Logger web site.

The website also gives you immediate alerts about problems and automatic reports to your email inbox.

The effect of a glycol-immersed probe on your results

Latency is the time it takes for something to change temperature, and different substances have vastly different latencies. If you apply a heat source to air, the air quickly becomes hot. If you apply a heat source to a liquid, it will heat up, but much more slowly.

So, if your logger is measuring air temperature, you will see rapid fluctuations in temperatures. Whereas, if your logger is measuring a liquid, those fluctuations will be much less pronounced.

In the graph below, we can see the Dual Sensor logger in action. The blue line represents air temperature, measured by the loggers internal sensor, while the pink line represents the temperature of the glycol in the vial, measured by the external probe.

You can see that the variation between minimum and maximum temperatures is much lower for the liquid temperature than for the air temperature.

Why this is great for vaccine fridges

This logger is specifically recommended for vaccine fridges

The Clever Logger logger has two jobs:

  1. to give us a record of the temperature, and
  2. to let us know if the temperature is out of range.

If we configure the Dual Sensor logger so that the alarms are triggered by the air temperature sensor, we will be notified immediately if the temperature goes outside our set limits.

However, since we are interested in the temperatures of the liquid vaccines, it is perfectly acceptable to log the temperature of the glycol liquid in the vial.

If the temperature starts to rise, we will find out about it from the air temperature sensor well before the liquid-immersed sensor reaches 8°, and hopefully in time to remedy the problem before the log shows a breach.

Clever Logger Dual Temperature Logger
probe not submersible

Probe cables are not waterproof

Note that only the metal tip of the probe is submersible. If liquid enters the join between the cable and the probe tip, the probe can be damaged.

Temperature Logger Specifications
Part No
CLD-01
Dimensions
66mm x 48mm x 10mm
Battery
Model CR2450.
Replace every 12 months
Weight
25g
Temperature Range
Internal sensor: -23°C to +60°C
External sensor: -40°C to +80°C
Accuracy
Internal Sensor:
±0.3℃ (0℃ to +60℃)
±0.3℃ to ±0.7℃ (other temperatures)
External Probe:
±0.5℃ (-20℃ to +40℃)
±1℃ (other temperatures)
Memory
~7,000 readings (approximately 24 days logging at 5 minute intervals)
Operating Temperature
-23°C to +60°C
Clever Logger temperature logger with external probe

Logger with Dual Temperature Sensors

QUICK SPECS
Model CLD-01
Type Temperature only with Dual Sensors
Temperature Range Internal sensor: -23°C to +60°C
External sensor: -40°C to +80°C
Humidity Range N/A
Battery Type CR2450
Battery Life Replace every 12 months
Accuracy Internal Sensor:
±0.3℃ (0℃ to +60℃)
±0.3℃ to ±0.7℃ (other temperatures)
External Probe:
±0.5℃ (-20℃ to +40℃)
±1℃ (other temperatures)
Offline Memory approx 24 days logging at 5 minute intervals
Clever Logger temperature logger with external probe

Logger with External Probe

QUICK SPECS
Model CLX-01
Type Temperature only with Probe
Temperature Range -40°C to 60°C
Can operate up to 80°C for short periods
Humidity Range N/A
Battery Type CR2450
Battery Life Replace every 12 months
Accuracy ±0.5℃ (-20℃ to +40℃)
±1℃ (other temperatures)
Offline Memory approx 24 days logging at 5 minute intervals

What is NATA?

The National Association of Testing Authorities (NATA) is the recognised national accreditation authority for analytical laboratories and testing service providers in Australia. It is an independent, not-for-profit organisation that provides independent assurance of technical competence. 

NATA accredits organisations to perform testing and inspection activities for their products and services. This gives consumers the assurance they need to make safe, healthy and reliable choices .

30-DAY FREE TRIAL

You're going to love Clever Logger

To prove it, we’ll send you a Starter Kit to try out for a whole month.

Set it up, have a play, explore the features – obligation free.

If you love it, just let us know.

If not, just send it back.